Fluke TI110 Thermal Imaging Camera, -20 → +250 °C, 160 x 120pixel Detector Resolution

RS Stock No.: 843-1538Brand: FlukeManufacturers Part No.: FLK-TI110 9HZ/FCA
brand-logo
View all in Thermal Imaging Cameras

Technical Document

Specifications

Brand

Fluke

Temperature Measurement Range

-20 → +250 °C

Detector Resolution

160 x 120pixel

Display Resolution

320 x 240pixel

Model Number

TI110

Thermal Sensitivity

≤0.1 @ 30 °C

Best Temperature Measurement Accuracy

±2 °C

Focus Type

Manual

Refresh Rate

9Hz

Display Size

3.5in

Spatial Resolution IFOV

3.39mrad

Application

Electrical, Industrial

Model Number p

Ti110

Weight

726g

Country of Origin

United States

Product details

Fluke Ti110 a3001 FC iFlex® Kit

Save money when you buy the Ti110 Thermal Imager, the Fluke a3001 FC iFlex and the Fluke 3000 FC Multimeter together in this great value bundle.

Fluke Ti110 Infrared Camera

IR resolution (FPA size): 160 x 120 FPA Uncooled Microbolometer
Spectral band: 7.5 μm to 14 μm (long wave)
Capture or refresh rate: 30 Hz version
NETD (thermal sensitivity): ≤0.10°C at 30°C target temp (100 mK)
FOV (field of view): 22.5° H x 31° V
IFOV (spatial resolution): 3.39 mRad
Temperature measurement range (not calibrated below -10°C): -20°C to +250°C (-4°F to 482°F)
Temperature measurement accuracy: ±2°C or 2% (at 25°C nominal, whichever is greater)
Focus mechanism: IR-OptiFlex™ focus system
IR Fusion® technology: PIP, full IR, full visible
Color alarms: High temperature
Standard palettes: Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Ultra Contrast™ palettes: Blue-Red, Grayscale, Ironbow
User definable spot markers: Three on camera and in SmartView®
Level and span control: Manual and auto
Minimum span in auto mode: 5°C
Minimum span in manual mode: 2.5°C
Minimum IR focus distance: 15.25 cm
Size: 28.4 x 8.6 x 13.5 cm
LCD display: 3.5 in diagonal (portrait format)
Visible camera: 2 megapixel industrial-grade

Fluke a3001 FC Wireless iFlex AC Current Module Fluke CONNECT™

The Fluke a3001 FC Wireless iFlex AC Current Module is a fully functional true-RMS current meter that wirelessly relays measurements to other Fluke Connect™ enabled master units
The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier
Measure up to 2500 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to
65000 readings
Inrush function
Magnetic hanging strap

Fluke 3000 FC Wireless Digital Multimeter Fluke CONNECT™

The Fluke 3000 FC Wireless Digital Multimeter is the ideal solution for professional technicians
Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC Multimeter has all the features you need to troubleshoot and repair many problems in electrical and electronic systems
AC and DC voltage measurements to 1000V
AC and DC current with 0.01 mA resolution
Continuity, resistance, diode test, capacitance and frequency measurements
MIN/MAX Recording
CAT III 1000 V, Cat IV 600 V
IP54

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

P.O.A.

Fluke TI110 Thermal Imaging Camera, -20 → +250 °C, 160 x 120pixel Detector Resolution

P.O.A.

Fluke TI110 Thermal Imaging Camera, -20 → +250 °C, 160 x 120pixel Detector Resolution
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Fluke

Temperature Measurement Range

-20 → +250 °C

Detector Resolution

160 x 120pixel

Display Resolution

320 x 240pixel

Model Number

TI110

Thermal Sensitivity

≤0.1 @ 30 °C

Best Temperature Measurement Accuracy

±2 °C

Focus Type

Manual

Refresh Rate

9Hz

Display Size

3.5in

Spatial Resolution IFOV

3.39mrad

Application

Electrical, Industrial

Model Number p

Ti110

Weight

726g

Country of Origin

United States

Product details

Fluke Ti110 a3001 FC iFlex® Kit

Save money when you buy the Ti110 Thermal Imager, the Fluke a3001 FC iFlex and the Fluke 3000 FC Multimeter together in this great value bundle.

Fluke Ti110 Infrared Camera

IR resolution (FPA size): 160 x 120 FPA Uncooled Microbolometer
Spectral band: 7.5 μm to 14 μm (long wave)
Capture or refresh rate: 30 Hz version
NETD (thermal sensitivity): ≤0.10°C at 30°C target temp (100 mK)
FOV (field of view): 22.5° H x 31° V
IFOV (spatial resolution): 3.39 mRad
Temperature measurement range (not calibrated below -10°C): -20°C to +250°C (-4°F to 482°F)
Temperature measurement accuracy: ±2°C or 2% (at 25°C nominal, whichever is greater)
Focus mechanism: IR-OptiFlex™ focus system
IR Fusion® technology: PIP, full IR, full visible
Color alarms: High temperature
Standard palettes: Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Ultra Contrast™ palettes: Blue-Red, Grayscale, Ironbow
User definable spot markers: Three on camera and in SmartView®
Level and span control: Manual and auto
Minimum span in auto mode: 5°C
Minimum span in manual mode: 2.5°C
Minimum IR focus distance: 15.25 cm
Size: 28.4 x 8.6 x 13.5 cm
LCD display: 3.5 in diagonal (portrait format)
Visible camera: 2 megapixel industrial-grade

Fluke a3001 FC Wireless iFlex AC Current Module Fluke CONNECT™

The Fluke a3001 FC Wireless iFlex AC Current Module is a fully functional true-RMS current meter that wirelessly relays measurements to other Fluke Connect™ enabled master units
The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier
Measure up to 2500 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to
65000 readings
Inrush function
Magnetic hanging strap

Fluke 3000 FC Wireless Digital Multimeter Fluke CONNECT™

The Fluke 3000 FC Wireless Digital Multimeter is the ideal solution for professional technicians
Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC Multimeter has all the features you need to troubleshoot and repair many problems in electrical and electronic systems
AC and DC voltage measurements to 1000V
AC and DC current with 0.01 mA resolution
Continuity, resistance, diode test, capacitance and frequency measurements
MIN/MAX Recording
CAT III 1000 V, Cat IV 600 V
IP54