Clampmeters

You are viewing 1 - 20 of 91 results
Display:
Results per page
20
  • 20
  • 50
  • 100
Price
(Price shown excludes VAT)
Part Details Brand Absolute Maximum AC Current Measurement Recently Introduced Absolute Maximum DC Current Measurement Absolute Maximum AC Voltage Measurement Absolute Maximum DC Voltage Measurement Absolute Maximum Resistance Measurement Model Number Calibrated AC Current Measurement Resolution DC Current Measurement Resolution Best DC Current Accuracy Clamp Meter Type Best AC Current Accuracy Best AC Voltage Accuracy Best DC Voltage Accuracy Height Width Safety Category Weight Temperature Measurement Resolution Safety Category Level Battery Life Battery Type Length AC Voltage Measurement Resolution Display Type Power Source Best Resistance Measurement Accuracy Best Temperature Measurement Accuracy Absolute Maximum Temperature Measurement Dimensions Resistance Measurement Resolution Jaw Capacity Busbars Functions Measured DC Voltage Measurement Resolution Maximum Conductor Size Minimum Operating Temperature Maximum Operating Temperature Safety Category Voltage
Fluke 325 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V
  • RS Stock No. 130-9783
  • Brand Fluke
  • Mfr. Part No. 325/T150/C550KIT
Fluke 400A ac new products only 400A dc 600V ac 600V dc 40kΩ 325 - - 0.1A 2 % Continuity Tester 2.5 % 1.5 % 1 % 207mm 75mm CAT III 600 V, CAT IV 300 V 283g 0.1°C CAT III, CAT IV - AAA, IEC LR03, NEDA 24A 34mm 0.1V Backlight Battery 1 % 1 % +400°C 34 x 75 x 207mm 10Ω - AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 325 Clamp Meter, Max Current 400A ac CAT III 600 V, CAT IV 300 V
  • RS Stock No. 131-5983
  • Brand Fluke
  • Mfr. Part No. 325/T150/C550KIT/D
Fluke 400A ac new products only - 600V ac 600V dc 40kΩ 325 - - 0.1A 2 % Continuity Tester 2.5 % 1.5 % 1 % 207mm 75mm CAT III 600 V, CAT IV 300 V 283g 0.1°C CAT III, CAT IV - AAA, IEC LR03, NEDA 24A 34mm 0.1V Backlight Battery 1 % 1 % +400°C 34 x 75 x 207mm 10Ω - AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 325 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V
  • RS Stock No. 131-0237
  • Brand Fluke
  • Mfr. Part No. 325/T150/C550KIT/F
Fluke 400A ac new products only 400A dc 600V ac 600V dc 40kΩ 325 - - 0.1A 2 % Continuity Tester 2.5 % 1.5 % 1 % 207mm 75mm CAT III 600 V, CAT IV 300 V 283g 0.1°C CAT III, CAT IV - AAA, IEC LR03, NEDA 24A 34mm 0.1V Backlight Battery 1 % 1 % +400°C 34 x 75 x 207mm 10Ω - AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 325 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V With RS Calibration
  • RS Stock No. 131-0220
  • Brand Fluke
  • Mfr. Part No. 325/T150/C550KIT
Fluke 400A ac new products only 400A dc 600V ac 600V dc 40kΩ 325 RSCAL - 0.1A 2 % Continuity Tester 2.5 % 1.5 % 1 % 207mm 75mm CAT III 600 V, CAT IV 300 V 283g 0.1°C CAT III, CAT IV - AAA, IEC LR03, NEDA 24A 34mm 0.1V Backlight Battery 1 % 1 % +400°C 34 x 75 x 207mm 10Ω - AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 303 clampmeter Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Fluke 317 clampmeter Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Fluke 325 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600V, CAT IV 300V Fluke 400A ac - 400A dc 600V ac 600V dc 40kΩ 325 - 10mA ac 10mA dc - Current, Voltage - - - 34mm 75mm CAT III 600V, CAT IV 300V 283g 0.1°C CAT III, CAT IV - AAA 207mm 0.1V ac LCD Battery - - +400°C 207 x 75 x 34mm 0.1Ω - AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 376 FC Clamp Meter, Max Current 2500 (Probe) A ac, 999.9 (Jaw) A ac, 999.9A dc CAT III 1000 V, CAT IV 600 V Fluke 2500 (Probe) A ac, 999.9 (Jaw) A ac - 999.9A dc 1000V ac 1000V dc 60kΩ 376 FC - 0.1 (Jaw) A ac, 1 (Probe) A ac 0.1A dc 2% ±5 Digits Voltage & Current Tester 2% ±5 Digits (Jaw), 3% ±5 (Probe) 1.5% ±5 Digits 1% ±5 Digits 43mm 83mm CAT III 1000 V, CAT IV 600 V 388g - CAT III, CAT IV - 2 AA, IEC LR6, NEDA 15A 246mm 1V ac Backlit LCD Battery 1% ±5 Digits - - 246 x 83 x 43mm - AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature 1V dc - -10°C +50°C 600 V, 1000 V
Fluke 323 Clamp Meter CAT III 600V, CAT IV 300V Fluke - - - 600V ac 600V dc 400Ω 323 - 100mA ac - - Current, Voltage ±2% +5 digits ±1% + 5 Digits - 34mm 75mm CAT III 600V, CAT IV 300V 265g - CAT III, CAT IV - AAA 207mm 0.1V ac LCD Battery - - - 207 x 75 x 34mm 0.1Ω - AC Current, AC Voltage, Continuity, DC Voltage, Resistance 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 324 Clamp Meter, Max Current 400A ac CAT III 600V, CAT IV 300V Fluke 400A ac - - 600V ac 600V dc 400Ω 324 - 10mA ac - - Current, Voltage - - - 34mm 75mm CAT III 600V, CAT IV 300V 208g 0.1°C CAT III, CAT IV - AAA 207mm 0.1V ac LCD Battery - - +400°C 207 x 75 x 34mm 0.1Ω - AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Resistance, Temperature 0.1V 30mm -10°C +50°C 300 V, 600 V
Fluke 365 Clamp Meter, Max Current 200A ac, 200A dc CAT III 600 V Fluke 200A ac - 200A dc 600V ac 600V dc 6000Ω 365 - 100mA ac 100mA dc ±2% + 5 Digits Continuity, Current, Resistance, Voltage ±2% +5 digits ±1.5% + 5 Digits ±1% + 5 Digits 46mm 65mm CAT III 600 V 275g - CAT lll - AA 225mm 0.1V ac LCD Battery ±1% + 5 Digits - - 225 x 65 x 46mm 0.1Ω - AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance 0.1V dc 18mm -10°C +50°C 600V
Fluke 374 FC Clamp Meter, Max Current 2500 (Probe) A ac, 600 (Jaw) A ac, 600A dc CAT III 1000 V, CAT IV 600 V Fluke 2500 (Probe) A ac, 600 (Jaw) A ac - 600A dc 600V ac 600V dc 6000Ω 374 FC - 0.1 (Jaw) A ac, 1 (Probe) A ac 0.1A dc 2% ±5 Digits Voltage & Current Tester 2% ±5 Digits (Jaw), 3% ±5 (Probe) 1.5% ±5 Digits 1% ±5 Digits 43mm 83mm CAT III 1000 V, CAT IV 600 V 388g - CAT III, CAT IV - 2 AA, IEC LR6, NEDA 15A 246mm 0.1V ac Backlit LCD Battery 1% ±5 Digits - - 246 x 83 x 43mm 10Ω - AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature 0.1V dc - -10°C +50°C 600 V, 1000 V
Fluke 375 FC Clamp Meter, Max Current 2500 (Probe) A ac, 600 (Jaw) A ac, 600A dc CAT III 1000 V, CAT IV 600 V Fluke 2500 (Probe) A ac, 600 (Jaw) A ac - 600A dc 600V ac 600V dc 60kΩ 375 FC - 0.1 (Jaw) A ac, 1 (Probe) A ac 0.1A dc 2% ±5 Digits Voltage & Current Tester 2% ±5 Digits (Jaw), 3% ±5 (Probe) 1.5% ±5 Digits 1% ±5 Digits 43mm 83mm CAT III 1000 V, CAT IV 600 V 388g - CAT III, CAT IV - 2 AA, IEC LR6, NEDA 15A 246mm 0.1V ac Backlit LCD Battery 1% ±5 Digits - - 246 x 83 x 43mm 10Ω - AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature 0.1V dc - -10°C +50°C 600 V, 1000 V
Fluke 376 Clamp Meter CAT III 1000 V, CAT IV 600 V Fluke - - - - - 60kΩ 376 - 0.1A 0.1A 2 % AC/DC Clamp Meter 2.5 % 1.5 % 1 % 246mm 43mm CAT III 1000 V, CAT IV 600 V 388g - CAT III, CAT IV - AA 83mm 0.1V Backlight Battery 1 % - - 83 x 43 x 246mm 0.1Ω 34mm AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance 0.1V - 10°C 50°C 600 V, 1000 V
Fluke 368 FC Leakage Current Clamp Meter Fluke - - - - - - 368 - 0.001mA - - Current Tester 1 % + 5 Digits - - 234mm 101mm CAT III 600 V 500g - CAT III 150 h 2 AA, Alkaline, IEC LR6, NEDA 15 A 46mm - LCD Battery - - - 46 x 101 x 234mm - 40 (Dia.)mm AC Current - 40 (Dia.)mm -10°C +50°C 600V
Fluke 381 Clamp Meter, Max Current 2500A ac, 999.9A dc CAT III 1000 V, CAT IV 600 V Fluke 2500A ac - 999.9A dc 1000V ac 1000V dc 60000Ω 381 - 100mA ac 100mA dc ±2% + 5 Digits Continuity, Current, Frequency, Resistance, Voltage ±2% +5 digits ±1.5% + 5 Digits ±1% + 5 Digits 50mm 88mm CAT III 1000 V, CAT IV 600 V 540g - CAT IV, CAT lll - AA 280mm 0.1V ac LCD Battery ±1% + 5 Digits - - 280 x 88 x 50mm 0.1Ω - AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Frequency, Resistance 0.1V dc 34mm -10°C +50°C 600 V, 1000 V
Fluke 771, mA process loop clamp meter Fluke - - 100mA dc - - - 771 - - 10µA dc ±1% + 5 Digits Current - - - 38mm 59mm - 260g - - 20 h AA 212mm - LCD Battery - - - 212 x 59 x 38mm - - - - 4.5mm -10°C +50°C -
FLUKE 773, mA PROCESS LOOP CLAMP METER Fluke - - 100mA dc - 30V dc - 773 - - 10µA dc ±1% + 5 Digits Current, Voltage - - 0.2% + 2 Digits 41mm 76mm - 420g - - 12 h AA 248mm - LCD Battery - - - 248 x 76 x 41mm - - AC Current, DC Voltage 0.01V dc 4.5mm -10°C +50°C -
Fluke 373 Clamp Meter, Max Current 600A ac CAT III 600 V, CAT IV 300 V Fluke 600A ac - - 600V ac 600V dc 6000Ω 373 - 100mA ac - - Capacitance, Continuity, Current, Resistance, Voltage ±2% +5 digits ±1% + 5 Digits ±1% + 5 Digits 45mm 85mm CAT III 600 V, CAT IV 300 V 370g - CAT II, CAT IV - AA 232mm 0.1V ac LCD Battery ±1% + 5 Digits - - 232 x 85 x 45mm 0.1Ω - AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Resistance 0.1V dc 32mm -10°C +50°C 300 V, 600 V
Fluke 902 FC Clamp Meter CAT III 600 V Fluke - - - - - 9999Ω 902 FC - 0.1A 0.1µA 1 % Continuity Tester 2 % 1 % 1 % 273mm 108mm CAT III 600 V 700g 0.1°C CAT III 12 h AA 62mm 0.1V LCD Battery 1.5 % 1 % +400°C 62 x 108 x 273mm - AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Resistance, Temperature 0.1V - -10°C +50°C 600V
Check Our Stock Volumes
Enter the quantity you require and click 'Check'. Stock information was updated at
. This information is updated daily so availability may vary at time of order placement.
RS Stock No:
I'm Looking For 
Compare list full
You can only compare 8 products at a time

View or remove your products on your Compare page
You are viewing 1 - 20 of 91 results