Technical Document
Specifications
Brand
Broyce ControlMonitoring Application
Phase, Voltage
Electrical Phase
3
Voltage Sensing Range
243 → 540V ac
Contact Configuration
SPDT
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Sequence
Time Delay
0.2 → 10s
Series
L
Length
66.5mm
Dimensions
66.5 x 17.5 x 89mm
Operating Temperature Range
+60°C
Height
89mm
Width
17.5mm
Maximum Operating Temperature
+60°C
Minimum Operating Temperature
-20°C
Maximum Voltage Sensed
540V
Terminal Type
Screw
Special Features
Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay
Number of Poles
2
Country of Origin
United Kingdom
Product details
LPRC/2 Phase Failure, Phase Sequence, Under and Over Voltage plus Time Delay
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!
Features and Benefits
Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) voltages
Selectable nominal voltages to suit most popular three wire or 4-wire supply voltages
Monitors own supply and detects if one or more phases exceed the set Under or Over voltage trip levels
Detects incorrect phase sequence, phase loss and neutral loss1
Adjustments for Under and Over voltage trip levels
Adjustment for time delay
Independent relay outputs - Under voltage monitoring / Over voltage monitoring
2 x SPDT relay output 5A
Green LED indication for supply status
Individual Red LED indication for both relay statuses
Approvals
UL Certification
Broyce Monitor Relays
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
Broyce ControlMonitoring Application
Phase, Voltage
Electrical Phase
3
Voltage Sensing Range
243 → 540V ac
Contact Configuration
SPDT
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Sequence
Time Delay
0.2 → 10s
Series
L
Length
66.5mm
Dimensions
66.5 x 17.5 x 89mm
Operating Temperature Range
+60°C
Height
89mm
Width
17.5mm
Maximum Operating Temperature
+60°C
Minimum Operating Temperature
-20°C
Maximum Voltage Sensed
540V
Terminal Type
Screw
Special Features
Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay
Number of Poles
2
Country of Origin
United Kingdom
Product details
LPRC/2 Phase Failure, Phase Sequence, Under and Over Voltage plus Time Delay
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!
Features and Benefits
Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) voltages
Selectable nominal voltages to suit most popular three wire or 4-wire supply voltages
Monitors own supply and detects if one or more phases exceed the set Under or Over voltage trip levels
Detects incorrect phase sequence, phase loss and neutral loss1
Adjustments for Under and Over voltage trip levels
Adjustment for time delay
Independent relay outputs - Under voltage monitoring / Over voltage monitoring
2 x SPDT relay output 5A
Green LED indication for supply status
Individual Red LED indication for both relay statuses
Approvals
UL Certification