Technical Document
Specifications
Brand
HartingCurrent Rating
10A
Gender
Male
Series
Han D
Type
Quick Lock Insert
Voltage Rating
120 V
IP Rating
IP65
Number Of Contacts
8
Body Orientation
Straight
Country of Origin
Germany
Product details
Han® 8D(U) Inserts
Han 8D Insert (stock nos. 363-8591 & 363-8608) uses crimp contacts these contacts must be ordered separately. See stock no. 114-7857 – typical of selection
For crimp tooling see stock no 114-7706 - typical of selection
All dedicated tooling is detailed within the Han® D Range
New Han-Quick Lock® inserts allow quick termination without screws or crimping. (stock nos. 700-8073 & 700-8076)
Warning
These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of a wrong connection
Approvals
UL, CSA, SEV
Han® 8D 10A Crimp Series
These Han® 8D (U) inserts are rated for use up to 10A. They are intended for use with hoods and housings contained within range 1. This hood and housing range is associated to a specific Harting 'Size' number identifier. See the 'compatibility' table for details of this relationship, and stock numbers of hoods and housings that are typical of this range.
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
HartingCurrent Rating
10A
Gender
Male
Series
Han D
Type
Quick Lock Insert
Voltage Rating
120 V
IP Rating
IP65
Number Of Contacts
8
Body Orientation
Straight
Country of Origin
Germany
Product details
Han® 8D(U) Inserts
Han 8D Insert (stock nos. 363-8591 & 363-8608) uses crimp contacts these contacts must be ordered separately. See stock no. 114-7857 – typical of selection
For crimp tooling see stock no 114-7706 - typical of selection
All dedicated tooling is detailed within the Han® D Range
New Han-Quick Lock® inserts allow quick termination without screws or crimping. (stock nos. 700-8073 & 700-8076)
Warning
These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of a wrong connection
Approvals
UL, CSA, SEV
Han® 8D 10A Crimp Series
These Han® 8D (U) inserts are rated for use up to 10A. They are intended for use with hoods and housings contained within range 1. This hood and housing range is associated to a specific Harting 'Size' number identifier. See the 'compatibility' table for details of this relationship, and stock numbers of hoods and housings that are typical of this range.