Technical Document
Specifications
Brand
CastleMaximum Sound Level
140dB
Minimum Sound Level
35dB
Resolution
0.1 dB
Accuracy Class
IEC 61672-1:2002 Class 2
DOSE Measurement
No
Weighting
A, C
Display Type
LCD
Battery Type
9V PP3
Fast/Slow Time Averaging
Both
Data Logging
No
Maximum Frequency
8kHz
Maximum Operating Temperature
+50°C
Minimum Frequency
20 Hz
Minimum Operating Temperature
-10°C
Model Number p
Sonus GA216B Class 2
Country of Origin
United Kingdom
Product details
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Sound Pressure (Lp) to 0.1 dB resolution
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Dimensions 60mm x 30mm (excluding pocket clip) x 135mm (210mm with microphone)
Weight 200g (without battery)
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2
Stock information temporarily unavailable.
Please check again later.
P.O.A.
Calibration type
No Calibration
1
P.O.A.
Calibration type
No Calibration
1
Technical Document
Specifications
Brand
CastleMaximum Sound Level
140dB
Minimum Sound Level
35dB
Resolution
0.1 dB
Accuracy Class
IEC 61672-1:2002 Class 2
DOSE Measurement
No
Weighting
A, C
Display Type
LCD
Battery Type
9V PP3
Fast/Slow Time Averaging
Both
Data Logging
No
Maximum Frequency
8kHz
Maximum Operating Temperature
+50°C
Minimum Frequency
20 Hz
Minimum Operating Temperature
-10°C
Model Number p
Sonus GA216B Class 2
Country of Origin
United Kingdom
Product details
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Sound Pressure (Lp) to 0.1 dB resolution
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Dimensions 60mm x 30mm (excluding pocket clip) x 135mm (210mm with microphone)
Weight 200g (without battery)
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2