Technical Document
Specifications
Brand
HoneywellSensor Function
Humidity Sensor
Output Type
Analogue
Interface Type
Analogue
Accuracy
±3.5%RH
Mounting Type
Through Hole
Pin Count
3
Operating Temperature Range
-40 → +85 °C
Minimum Operating Temperature
-40 °C
Maximum Operating Temperature
+85 °C
Minimum Operating Supply Voltage
4 V
Maximum Operating Supply Voltage
5.8 V
Package Type
SIP
Length
21.66mm
Height
2.03mm
Series
HIH-4000
Width
4.27mm
Sensor Gain
-4mV/°C
Dimensions
21.66 x 4.27 x 2.03mm
Product details
HIH-4000/4020/4021 Series Humidity Sensors, Honeywell
The HIH-4000 series has been specifically designed for use in high volume OEM (Original Equipment Manufacturer) applications. These sensors utilise a near linear voltage output making direct input to a controller or other devices possible. They are ideally suited for low drain, battery operated systems with a typical current draw of only 200 μA. Potential Applications:Refrigeration equipmentHVAC equipmentMedical equipmentDryingMeteorologyBattery-powered systemsOEM assemblies
Features:Moulded thermoset plastic housingNear linear voltage output vs %RHLaser-trimmed interchangeabilityEnhanced accuracy, fast responseFast response timeStable, low drift performanceChemically resistant
Temperature & Humidity Sensors, Honeywell
Stock information temporarily unavailable.
Please check again later.
P.O.A.
50
P.O.A.
50
Technical Document
Specifications
Brand
HoneywellSensor Function
Humidity Sensor
Output Type
Analogue
Interface Type
Analogue
Accuracy
±3.5%RH
Mounting Type
Through Hole
Pin Count
3
Operating Temperature Range
-40 → +85 °C
Minimum Operating Temperature
-40 °C
Maximum Operating Temperature
+85 °C
Minimum Operating Supply Voltage
4 V
Maximum Operating Supply Voltage
5.8 V
Package Type
SIP
Length
21.66mm
Height
2.03mm
Series
HIH-4000
Width
4.27mm
Sensor Gain
-4mV/°C
Dimensions
21.66 x 4.27 x 2.03mm
Product details
HIH-4000/4020/4021 Series Humidity Sensors, Honeywell
The HIH-4000 series has been specifically designed for use in high volume OEM (Original Equipment Manufacturer) applications. These sensors utilise a near linear voltage output making direct input to a controller or other devices possible. They are ideally suited for low drain, battery operated systems with a typical current draw of only 200 μA. Potential Applications:Refrigeration equipmentHVAC equipmentMedical equipmentDryingMeteorologyBattery-powered systemsOEM assemblies
Features:Moulded thermoset plastic housingNear linear voltage output vs %RHLaser-trimmed interchangeabilityEnhanced accuracy, fast responseFast response timeStable, low drift performanceChemically resistant