LEM LV Series Current Transformer, 14A Input, 14:1, 25 mA Output, 12 → 15 V

RS Stock No.: 286-361Brand: LEMManufacturers Part No.: LV 25-P
brand-logo
View all in Current Transformers

Technical Document

Specifications

Brand

LEM

Current Ratio

14:1

Sensor Technology

Closed Loop

Supply Voltage

12 → 15 V

Input Current

14A

Output Current

25 mA

Overall Height

16.45mm

Overall Width

26mm

Overall Depth

29.2mm

Minimum Temperature

0°C

Maximum Temperature

+70°C

Series

LV

Mounting Type

PCB Mount

Width

26mm

Country of Origin

China

Product details

PCB Mount

For the electronic measurement of currents, DC, AC, pulsed, providing galvanic separation between the primary circuit and the secondary circuit.

A Hall effect device, which provides galvanic isolation between primary and secondary circuits
Self extinguishing plastic case
Ideal for measuring voltages associated with a.c. and d.c. impluse circuits
An external resistor must inserted in series with the primary circuit to measure a voltage
Instantaneous output
Suitable for d.c. power supplies, UPS's, instruments, metering and relay systems
Closed loop operation

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

P.O.A.

LEM LV Series Current Transformer, 14A Input, 14:1, 25 mA Output, 12 → 15 V

P.O.A.

LEM LV Series Current Transformer, 14A Input, 14:1, 25 mA Output, 12 → 15 V
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

LEM

Current Ratio

14:1

Sensor Technology

Closed Loop

Supply Voltage

12 → 15 V

Input Current

14A

Output Current

25 mA

Overall Height

16.45mm

Overall Width

26mm

Overall Depth

29.2mm

Minimum Temperature

0°C

Maximum Temperature

+70°C

Series

LV

Mounting Type

PCB Mount

Width

26mm

Country of Origin

China

Product details

PCB Mount

For the electronic measurement of currents, DC, AC, pulsed, providing galvanic separation between the primary circuit and the secondary circuit.

A Hall effect device, which provides galvanic isolation between primary and secondary circuits
Self extinguishing plastic case
Ideal for measuring voltages associated with a.c. and d.c. impluse circuits
An external resistor must inserted in series with the primary circuit to measure a voltage
Instantaneous output
Suitable for d.c. power supplies, UPS's, instruments, metering and relay systems
Closed loop operation