(Price shown excludes VAT)
Part Details Brand Loop Impedance Test Type Calibrated Insulation Test Voltage Maximum Voltage Measurement Test Type Interface Type Continuity Test Current RCD Test Type Test Standards Model Number p Weight Dimensions Width Height Length Battery Type Maximum Continuity Resistance Safety Category Minimum Continuity Resistance Safety Category Voltage IP Rating Plug Type Display Type Maximum Operating Temperature Safety Category Level Minimum Operating Temperature Power Source
1663 SCH-SPIKES, FLUKE 163 SCH, ES165X E
  • RS Stock No. 182-9957
  • Brand Fluke
  • Mfr. Part No. 1663 SCH-SPIKES
Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - -
1664 SCH-SPIKES, FLUKE 163 SCH, ES165X E
  • RS Stock No. 182-9958
  • Brand Fluke
  • Mfr. Part No. 1664 SCH-SPIKES
Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - -
FLUKE 1663 UK, FLUKE T6-600/EU, DMS COMP Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - -
FLUKE 1664FC UK, FLUKE T6-1000/EU, DMS C Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - -
FLUKE-1664FC DE, DMS COMPL/PROF,FLUKEPAC
  • RS Stock No. 183-0957
  • Brand Fluke
  • Mfr. Part No. 1664 DE /BACKPACK
Fluke - - - - - - - - - - - - - - - - - - - - - - - - - - -
1663 SCH-CLAMP/F,FLUKE 1663 SCH, FLUKE 3
  • RS Stock No. 177-1407
  • Brand Fluke
  • Mfr. Part No. 1663 SCH-CLAMP/F
Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc - - 10mA - - 1663 1.3kg 10 x 25 x 12.5cm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK LCD +40°C CAT III, CAT IV -10°C Battery
1663 UK-CLAMP, FLUKE 1663 UK, FLUKE 324 Fluke - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity USB 10mA A/F, AC, B/B+, G, S IEC 60364 1663 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK - -40°C CAT III, CAT IV -10°C Battery
1664 SCH-CLAMP/F,FLUKE 1664 SCH, FLUKE 3
  • RS Stock No. 177-1408
  • Brand Fluke
  • Mfr. Part No. 1664 SCH-CLAMP/F
Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc - - 10mA - - 1664 1.3kg 10 x 25 x 12.5cm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK LCD +40°C CAT III, CAT IV -10°C Battery
1664 UK-CLAMP,FLUKE 1664FC UK, FLUKE 325 Fluke - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity BLE, USB 10mA A/F, AC, B/B+, G, S IEC 60364 1664FC 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK - -40°C CAT III, CAT IV -10°C Battery
RSCAL(1769810) 1663 UK-CLAMP, FLUKE 1663 Fluke - - 50 V, 100 V, 250 V, 500 V, 1000 V 600V ac/dc - - 10mA A, AC - 324 208g 207 x 75 x 34mm 75mm 34mm 207mm AA 30Ω CAT III 600 V, CAT IV 300 V 20Ω 300 (CAT IV) V, 600 (CAT III) V IP40 - Backlight +400°C CAT III, CAT IV -10°C Battery
RSCAL(1769811) 1664 UK-CLAMP,FLUKE 1664F Fluke - - 50 V, 100 V, 250 V, 500 V, 1000 V 600V ac/dc - - 10mA A, AC - 325 283g 207 x 75 x 34mm 75mm 34mm 207mm AA 30Ω CAT III 600 V, CAT IV 300 V 20Ω 300 (CAT IV) V, 600 (CAT III) V IP40 - Backlight +400°C CAT III, CAT IV -10°C Battery
UKAS(1769810) 1663 UK-CLAMP, FLUKE 1663 Fluke - - 50 V, 100 V, 250 V, 500 V, 1000 V 600V ac/dc - - 10mA A, AC - 324 208g 207 x 75 x 34mm 75mm 34mm 207mm AA 30Ω CAT III 600 V, CAT IV 300 V 20Ω 300 (CAT IV) V, 600 (CAT III) V IP40 - Backlight +400°C CAT III, CAT IV -10°C Battery
UKAS(1769811) 1664 UK-CLAMP,FLUKE 1664F Fluke - - 50 V, 100 V, 250 V, 500 V, 1000 V 600V ac/dc - - 10mA A, AC - 325 283g 207 x 75 x 34mm 75mm 34mm 207mm AA 30Ω CAT III 600 V, CAT IV 300 V 20Ω 300 (CAT IV) V, 600 (CAT III) V IP40 - Backlight +400°C CAT III, CAT IV -10°C Battery
T6-1000 Electrical Tester,1000V Fluke - - - - - - - - - T6-1000 350g 61.1 x 43.8 x 259.3mm 43.8mm 259.3mm 61.1mm AA IEC LR6 - CAT III 1000 V, CAT IV 600 V - 600 V, 1000 V - - LCD +50°C CAT III, CAT IV -10°C -
1662 Installation Tester UK Version Fluke Phase to Earth, Phase to Neutral - 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity - 10mA - - 1662 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK - - CAT III, CAT IV - Battery
1664 FC tester and DMS Software UK Ver.
  • RS Stock No. 113-5132
  • Brand Fluke
  • Mfr. Part No. FLK-1664FC DMS UK
Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity BLE, USB 10mA A/F, AC, B/B+, G, S - 1664FC 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK - - CAT III, CAT IV - Battery
1663 Installation Tester UK Version Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity USB 10mA A/F, AC, B/B+, G, S - 1663 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK - - CAT III, CAT IV - Battery
1664 FC Installation Tester UK Version Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity BLE, USB 10mA A/F, AC, B/B+, G, S - 1664FC 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 UK - - CAT III, CAT IV - Battery
Installation Tester 1664 EU Schuko. Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc - BLE, USB 10mA A/F, AC Type, B/B+, G, S - 1664FC 1.3 (with Battery)kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 - LCD - CAT III, CAT IV - Battery
Fluke 1651B Electrical Tester RS Calibration Fluke 3 Wire RSCAL 250 V, 500 V, 1000 V 500V ac Continuity, Wiring Polarity UK Mains 200mA AC Type BS 7671, EN 61010-I, HD 384, IEC 60364 1651B 1.3kg 100 x 250 x 125mm 250mm 125mm 100mm AA 2000Ω CAT III 500 V, CAT IV 300 V 20Ω 300 V, 500 V IP40 Type F - Schuko plug, Type G - British 3-pin LCD +40°C CAT III, CAT IV -10°C Battery, Mains
Check Our Stock Volumes
Enter the quantity you require and click 'Check'. Stock information was updated at