Technical Document
Specifications
Brand
CelducMaximum Load Current
40 A
Mounting Type
Panel Mount
Maximum Load Voltage
265 V rms
Minimum Load Voltage
115 V ac
Maximum Control Voltage
10 V dc
Minimum Control Voltage
0 V
Switching Type
Analogue Control
Control Voltage Range
0 → 10 V dc
Minimum Load Current
10 mA
Range
SG4
Number of Poles
1
Terminal Type
Screw
Output Device
Triac
Relay Type
Single Phase angle controller
Load Voltage Range
115 → 265V ac
Maximum Turn On Time
10ms
Series
SG4
Dimensions
100 x 73.5 x 39.5mm
Depth
73.5mm
Height
39.5mm
Off State Leakage Current
5 mA
Length
100mm
Operating Temperature Range
-40 → +85°C
Standards Met
CE, EAC
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+85°C
Country of Origin
France
Product details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.
Proportional and Power
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
CelducMaximum Load Current
40 A
Mounting Type
Panel Mount
Maximum Load Voltage
265 V rms
Minimum Load Voltage
115 V ac
Maximum Control Voltage
10 V dc
Minimum Control Voltage
0 V
Switching Type
Analogue Control
Control Voltage Range
0 → 10 V dc
Minimum Load Current
10 mA
Range
SG4
Number of Poles
1
Terminal Type
Screw
Output Device
Triac
Relay Type
Single Phase angle controller
Load Voltage Range
115 → 265V ac
Maximum Turn On Time
10ms
Series
SG4
Dimensions
100 x 73.5 x 39.5mm
Depth
73.5mm
Height
39.5mm
Off State Leakage Current
5 mA
Length
100mm
Operating Temperature Range
-40 → +85°C
Standards Met
CE, EAC
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+85°C
Country of Origin
France
Product details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.