Technical Document
Specifications
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
5V dc
Number of Outputs
4
Mount Type
Chassis
Power
175W
Minimum Operating Temperature
0°C
Maximum Operating Temperature
70°C
Length
127mm
Weight
250g
Standards/Approvals
EN 60601-1-2:2007, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-6-2:2005, EN 61000-6-3:2007
Width
76.2mm
Depth
31.75mm
Series
NV1
Maximum Input Voltage
370, 265V dc
Efficiency
90%
Hazardous Area Certification
No
Minimum Input Voltage
90V ac
Country of Origin
United Kingdom
Product details
175-180W, Universal Input, 3x5 inch, Single & Multi Outputs, NV175 Series
Miniature size 3x5 inch, high power density
Low profile, fits 1U applications
No minimum load
Up to 90% efficiency
Adjustable output voltage on outputs 1, 2 and 3
Medical safety approved to EN 60601-1
Power factor correction to EN 61000-3-2
EMC meets EN 55022-B (as per CISPR.22)
Remote sense on outputs 1 & 2
Short circuit and over voltage and over temperature protection
Approvals
UL recognised component for US, CSA
Standards
EN 60950-1, UL 60950-1, CSA 22.2 No. 60950, IEC 60950-1, IEC 60601-1
Switch Mode - TDK-Lambda
Stock information temporarily unavailable.
P.O.A.
1
P.O.A.
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
5V dc
Number of Outputs
4
Mount Type
Chassis
Power
175W
Minimum Operating Temperature
0°C
Maximum Operating Temperature
70°C
Length
127mm
Weight
250g
Standards/Approvals
EN 60601-1-2:2007, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-6-2:2005, EN 61000-6-3:2007
Width
76.2mm
Depth
31.75mm
Series
NV1
Maximum Input Voltage
370, 265V dc
Efficiency
90%
Hazardous Area Certification
No
Minimum Input Voltage
90V ac
Country of Origin
United Kingdom
Product details
175-180W, Universal Input, 3x5 inch, Single & Multi Outputs, NV175 Series
Miniature size 3x5 inch, high power density
Low profile, fits 1U applications
No minimum load
Up to 90% efficiency
Adjustable output voltage on outputs 1, 2 and 3
Medical safety approved to EN 60601-1
Power factor correction to EN 61000-3-2
EMC meets EN 55022-B (as per CISPR.22)
Remote sense on outputs 1 & 2
Short circuit and over voltage and over temperature protection
Approvals
UL recognised component for US, CSA
Standards
EN 60950-1, UL 60950-1, CSA 22.2 No. 60950, IEC 60950-1, IEC 60601-1